front-line

ประเภทสินค้า
KSB /Etanorm R
KSB /Etanorm R

Horizontal, long-coupled, single-stage volute casing pump with ratings and main dimensions to EN 733 in back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings. Design to ATEX.

 
KSB /Etanorm R
KSB /Etanorm R
KSB /Etanorm R

Applications

Spray irrigation, irrigation, drainage, district heating,

water supply systems, heating and air-conditioning systems,

condensate transport, swimming pools, fire-fighting systems,

handling of hot water, cooling water, fire-fighting water, oil,

brine, drinking water, brackish water, service water, etc.

 

Overview of technical data

Type of impeller

Closed / Radial

Type of installation

Long- coupled

Impeller material (EN standard)

1. 4408 / A743 GR CF8 M;CC480K-GS / B30 C90700;JL1040 / A 48 CL 35B

Type of bearing

Ball bearings

Drive frequency

50 Hz / 60 Hz

Maximum speed of rotation

3. 500 1/min

Maximum flow rate

740 m³/h

Maximum discharge-side pressure

16 bar

Suitable for drinking water

Yes

Casing material (EN standard)

1. 4408 / A743 GR CF8 M;CC480K-GS / B30 C90700;JL1040 / A48CL35B;JS1030 / A536 GR 60-40-18

No. of impeller entries

Single entry

Casing material

Cast iron; Stainless steel;Nodular cast iron;Bronze

Minimum flow rate

1, 50 m³/h

Suction characteristics

Non- priming

Drive voltage

Low voltage

eClass assignment

36410000; 36410100;36410101

Pull-out design

Yes

Pump set location

Dry installed

Explosion protection

IP 55

Max. permissible fluid temperature

140 ******

UNSPSC classification

4015150300

Main applications

Industry and process engineering; Water;Energy;Building services

Type of installation

Stationary

Type of casing

Volute casing

Type of connection

Flange

Type of lubrication

Grease / Oil lubrication

Type of drive

Electric motor

Installation position

Horizontal

Shaft material (EN standard)

1. 4571;C45+N

Type of coupling

Direct

Shaft seal type

Mechanical seal; Gland packing

Maximum head

160, 00 m

Maximum rated pressure (discharge)

PN 16

Minimum head

2, 00 m

Standard

EN; EN / ANSI

Nozzle position

End suction

Casing partition

Radially split

Guaranteed to be silicon-free

Yes

 

Etanorm/Etanorm R – Standardised Water Pump

 
Online:  17
Visits:  90,820
Today:  42
PageView/Month:  2,619