front-line

ประเภทสินค้า
ประเภทสินค้า : KSB » KSB /Omega Axially split pumps
KSB /Omega Axially split pumps
KSB /Omega Axially split pumps

Design 
Single-stage, axially split volute casing

pump for horizontal or vertical installation,

with double-entry radial impeller, mating

flanges to DIN, ISO, BS or ANSI. 

Applications 
Handling of raw, pure and service water as well

as seawater in water treatment plants,

irrigation and drainage pumping stations,

power stations, fire-fighting systems,

shipbuilding and the petrochemical industry.

 
KSB /Omega Axially split pumps
KSB /Omega Axially split pumps
KSB /Omega Axially split pumps
KSB /Omega Axially split pumps

Overview of technical data

Type of impeller

Closed; Radial

Type of installation

Long- coupled

Maximum drive rating

1. 500 kW

Impeller material (EN standard)

BRONZE; CHROMSTAHL;DUPLEXSTAHLGUSS;SUPER DUPLEX

Type of bearing

Rolling element and plain bearings

Drive frequency

50 Hz / 60 Hz

Maximum speed of rotation

3. 500 1/min

Maximum flow rate

2. 800 m³/h

Maximum discharge-side pressure

25 bar

Suitable for drinking water

Yes

Casing material (EN standard)

GRAUGUSS

No. of impeller entries

Double entry

Casing material

Cast iron; Duplex steel;Cast duplex steel;Nodular cast iron

Minimum flow rate

50 m³/h

Suction characteristics

Non- priming

Drive voltage

Low voltage, high voltage

eClass assignment

36410103; 36410100;36410101;36410000

Pump set location

Dry installed

Max. permissible fluid temperature

80 ******

Main applications

Industry and process engineering; Water;Energy;Building services;Mining / Dredges

Type of installation

00

Type of casing

Volute casing

Type of connection

Flange

Type of lubrication

Grease / Oil lubrication

Type of drive

Electric motor

Installation position

Horizontal or vertical

Shaft material (EN standard)

13 % CHROMSTAHL;DUPLEXSTAHL

Type of coupling

Direct; Gear

Shaft seal type

Gland packing; Mechanical seal

Maximum head

170, 00 m

Maximum rated pressure (discharge)

PN 10, PN 16, PN 25

Minimum head

7, 00 m

Nozzle position

In- line

Casing partition

Axially split

 

 
Online:  2
Visits:  113,868
Today:  52
PageView/Month:  1,865